An oil-sludge mixture is cooled with cooling water. Because of the high temperature difference, the mixture is cooled in a tube bundle cascade in 3-4 passes. The oil-sludge mixture circulates in a circle until it falls below the maximum permissible outlet temperature (60°C). The oil-sludge mixture flows through the pipes while the cooling water flows around the pipes. Cleaning covers are provided on the front of each step for cleaning purposes.
Key data:
- Output: 87 kW
- Inlet- | outlet temperature tube side: 85|55 °C
- Inlet- | outlet temperature shell side: 36|43,5 °C
- Tubes Ø 33,7 x 2 mm made of stainless steel 1.4571
- Tube plate and shell made of stainless steel 1.4571
- Dimensions heat exchanger: 1.700 x 1.700 x 1.900 mm
- Layout| Design | process planning | production