CONVERSION OF FLUE GAS CONDENSATION
The existing flue gas condensation plant had to be completely rebuilt. The ECO had to be renewed and better adapted to the process conditions, as well as the dehumidification LUVO, which had already been closed completely blind due to massive damage. The two-stage ECO was designed in such a way that the two district heating networks can be used completely separately. Furthermore, a low-temperature condenser bundle was retrofitted. All cleaning and flushing equipment was renewed. All work such as design, construction and installation was carried out in close coordination with the operator.
KEY datA:
- ECO stage 1
- ECO stage 2 together 530 kW
- Heat output of condensers 1000 kW
- Welded stainless steel LUVO
- Heat output LUVO 748 kW
- All heat exchanger tubes made of stainless steel 1.4571
- Casing parts, as well as tube and duct parts made of stainless steel 1.4571
- Engineering (VT design & construction)
- Installation and transport
- Installation site: Toblach Südtriol